Review Article Volume 9 Issue 6
Department of Orthodontics, Bahrain
Correspondence: Harshad Ghorpade, Department of Orthodontics, Bahrain
Received: August 30, 2019 | Published: November 23, 2018
Citation: Ghorpade H. Comparison of shear bond strength of four different flowable composites and orthodontic resin with and without prior adhesive primer application - an in vitro study. J Dent Health Oral Disord Ther. 2018;9(6):504-506. DOI: 10.15406/jdhodt.2018.09.00437
Need for the study: The most popular bonding method in orthodontics has been based on the acid etch technique which was introduced in 1955 by Buonocore,1 and modified for orthodontic purposes in 1960s by Newman.2 The important step in this technique to precondition the enamel surface with a 37% orthophosphoric acid solution or gel for approximately 30 seconds and dissolve the minerals of the enamel for the direct bonding of orthodontic brackets was reported.2 Traditional orthodontic bracket bonding systems required the use of a 3-step procedure involving 3 separate agents- an enamel conditioner, a priming agent, and an adhesive resin.3 Development of flowable composites used for bonding of orthodontic brackets onto tooth surfaces has greatly improved with the qualities that have been of most interest including bond strength, adequate working time. It reduces the number of steps during bonding, and the potential errors related to contamination during bonding.4 Eliminating the application of primer would be advantageous for orthodontic bracket bonding which can reduce the number of steps.
However, although eliminating the placement of a bonding agent after a separate etching process would result in a comparable number of steps to using a one-step etch/bond agent, there would be a cost advantage.5 Flowable composites also show two desirable clinical handling characteristics that have not existed for composites until very recently: 1. Non stickiness, so that material could be packed or condensed, and 2. Fluid injectability.6 There are still few studies available on the bonding characteristics of flowable composites and the effect of these materials on the enamel surfaces during debonding.7−10 Keeping in mind all the above mentioned points, this study will be aimed to compare the shear bond strength of the brackets bonded with conventional orthodontic resin and four different flowable composites with and without prior adhesive primer application.
A study was conducted to evaluate the shear bond strength & site of bond failure for two visible light cured composites & one resin modified glass ionomer cement. It was concluded that if bond strength was the primary consideration for choosing an adhesive, then composite should be utilized.11 An in vitro study evaluated the effect of repeated bonding on the shear bond strength of orthodontic brackets using a composite resin orthodontic adhesive. In conclusion, the authors stated that rebonded brackets had significantly lower & inconsistent shear bond strength.12
A study was done to compare the shear bond strength of two light cured hydrophilic bonding systems with a hydrophobic bonding system under different enamel surface condition. It concluded that non-contaminated enamel surfaces had the highest bond strengths for both the hydrophilic and hydrophobic materials. When using a hydrophobic primer, if the etched surface is contaminated with saliva before primer application, it may be necessary to re-etch before proceeding with the bonding procedure. If the contamination occurred after the primer had been placed and cured, simple drying and reapplication of the primer may be necessary. The hydrophilic primers also showed improved bond strength with reapplication of primer after saliva contamination.13 A study was conducted to determine the shear bond strength values of different flowable composites without primer application in comparison with a conventional orthodontic adhesive with primer application. The study concluded that flowable composite with no intermediate bonding resin could be conveniently applied for orthodontic bracket bonding.10 An in vitro study was conducted to compare the shear bond strength of organically modified ceramic matrix - ORMOCER to that of traditional composite. It was concluded that Ormocer could potentially have orthodontic applications if available in a more flowable form.14 A study was done to determine the shear bond strength value of a dental flowable composite - Dentiflow & the mode of its bond failure after debonding. It was concluded that Dentiflow had the same shear bond strength as traditional composite resins & similar bond failure patterns.15 An in vitro study was conducted to compare the shear bond strength of a nano- hybrid restorative composite with that of a traditional adhesive material when used for bonding orthodontic brackets. It was concluded that nano- filled composite could potentially be used to bond orthodontic brackets to the tooth.16
Objectives of the study
Source of data
Total 5 different composite materials obtained from respective manufacturer.
Methods of collection of data
Extracted 100 premolar will be collected and study conducted in Goa dental college & Hospital, Bambolim Goa, India.
Type of study: Prospective Study.
Materials used
Transbond XT, 3M UNITEK (manufacturer)
Inclusion criteria
Exclusion criteria
A total of 100 sound-extracted human premolars will be stored in 0.5% chloramine T solution after extraction. The premolars will be mounted in a self-cure acrylic block. The buccal crown surface of each premolar will be rinsed and dried after a 15-second polish with fluoride free pumice slurry. 100 teeth will be divided into 5 experimental groups with 20 teeth in each experimental group (N=20) and 4 experimental groups (N=20X4=80) of flowable composites (Transbond supreme LV, 3M unitek; G-aenial Universal flow, GC India Ltd; Admira flow, Voco; Tetric Flow, Ivoclar-Vivadent) will be used to test shear bond strength and one experimental group (N=20) of conventional composite (Transbond XT, 3M unitek) will be used to test shear bond strength. For all the experimental groups, the buccal enamel surface will be etched with 37% phosphoric acid gel (Etch) for 30 seconds, rinsed for 15 seconds, and dried with oil-free and moisture-free air for 20 seconds until the enamel will become faintly white. After acid etching, for each experimental group, half of the specimens (N=10) a thin layer of Transbond XT primer will be applied and light cured according to manufacturer's instructions. Primer will not be applied for another half of the specimen (N=10) of each experimental group. Composites will be applied to the bracket base, and the bracket will be positioned on the tooth and pressed firmly with a Hollenback carver to expel the excess adhesive. Then, the composite will be light cured for 20 seconds from the occlusal edge and 20 seconds from the gingival bracket edge.
The bracketed teeth will then be immersed in sealed containers of deionized water and placed in an incubator at 37oC for 72 hours to permit adequate water absorption and equilibration, and then the tests for examining the shear bond strength will be performed. The specimens will be secured in a jig attached to the base plate of a universal testing machine. A chisel-edge plunger will be mounted in the movable crosshead of the testing machine and positioned so that the leading edge will be aimed at the enamel-composite interface before being brought into contact. A crosshead speed of 0.5 mm/min will be used. After debonding, each specimen will be examined under a stereoscopic zoom microscope (10X) to identify the location of the bond failure. The residual composite remaining on the premolar will be assessed by using the remnant index (ARI), where each specimen will be scored according to the amount of material remaining on the enamel surface.
Descriptive statistics including means (MPa) and standard deviations (SD) will be calculated for the shear bond strength analysis. A two way analysis of variance (ANOVA) and Student-Newman-Keuls multiple comparison tests will be used to determine the statistical significance of any difference in mean shear bond strengths among the 10 groups. The ARI will be analysed for percentage and frequency of fracture type, and a chi-square test will be used as the statistical test. Significance for all statistical tests will be predetermined at P<0.05.
Does the study require any investigations or interventions to be conducted in patients or other humans?
No.
A study was conducted to determine the shear bond strength values of different flowable composites without primer application in comparison with a conventional orthodontic adhesive with primer application. The study concluded that flowable composite with no intermediate bonding resin could be conveniently applied for orthodontic bracket bonding.10It was also concluded that if bond strength was the primary consideration for choosing an adhesive, then composite should be utilized.11
None.
The author declares that there is no conflicts of interest.
©2018 Ghorpade. This is an open access article distributed under the terms of the, which permits unrestricted use, distribution, and build upon your work non-commercially.